Deciding on the seating arrangement for a restaurant can be a tough assignment, regardless of whether a new-build or refurbishment.
A few issues to consider include:
- The size of the restaurant.
- The type of restaurant.
- The desired aesthetic.
- Safety and hygiene.
- The organisation of functions.
[edit] Essential space planning
In space arranging, the dining area should involve a large portion of the all-out zone, kitchen and stockpiling and the preparation area should occupy the rest of the space. These should be balanced if a waiting area or a bar is planned, yet the approximate percentages for the total area should be:
Planning the seating will depend upon what kind of restaurant is intended. For example, banquet seating may require as little as 10 square feet for every individual, while high-end dining may require double that amount.
It is normal for most restaurants or bistros that have a general menu to average around 15 square feet for each individual. This includes space required for traffic paths, hold-up stations, clerk, and so on.
In a hypothetical restaurant, for example:
- The floor plan area = 5,000 square feet
- There are 200 seats
- 60% dining area = 3,000 square feet
- 40% kitchen = 2,000 square feet.
[edit] Seating arrangement
If the structure has 2,800 square feet accessible, the dining zone ought to be roughly 1,680 square feet, which would hold 112 seats. The kitchen and storage zone ought to be 1,120 square feet. The subtleties of the floor plan and area in square feet to be allotted to the kitchen and dining area rely upon the proprietor's thoughts and how they can be applied to the floor plan.
The area allocated to every patron depends upon the kind of dining establishment that is required - whether it is a fine dining establishment, full-service restaurant, counter service, fast food restaurant, a lodging/club or a banquet hall.
[edit] A few rules
- High-end dining: 18 – 20 square ft
- Full-Service Restaurant Dining: 11 – 14 square ft
- Counter Service: 17 – 19 square ft
- Fast Food Minimum: 12 – 15 square ft
- Table Service, Hotel/Club: 16 – 20 square ft
- Banquet, Minimum: 10 – 11 Ssquare ft
For safety reasons and to account for the free flow of traffic of diners and servers, the route between seats ought to be in any event 18 inches wide and 4 – 5 feet for every table, including seat space. This takes into consideration the free movement of servers between stations and kitchen and gives enough space for the visitors to move around.
It is important for security reasons that there is sufficient space for the guests and staff to move around and that the walkways are clear, particularly in the event of fire.
Deciding the zone for wait stations should also be considered when designing floor plans. One small station should take up 6 – 10 square feet, adequate for 20 diners. One large focal station ought to be somewhere in the range of 25 – 40 square feet. This would be adequate for 60 diners.
If the restaurant is to have a bar, 500mm to 550mm length of standing room for each individual should be provided. If the bar is to have seating, there should be 600mm between bar stools.
[edit] Furniture arrangement
Some broad, furniture design guidelines include:
- Table Height: 735mm – 760mm
- Bar Height 760mm – 915mm – 1065mm
- Seat Height 432mm – 457mm
- Bar Stool Height 735mm – 760mm.
Once the restaurant floor plan has been designed, the restaurant's style and furniture can be decided. This depends generally on the type of dining establishment and what sort of customers are expected. Depending on the size of the restaurant, there are numerous alternatives to consider, including the use of restaurant corners, tables, and seats.
[edit] Related articles on Designing Buildings
Featured articles and news
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Heat pumps, vehicle chargers and heating appliances must be sold with smart functionality.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.
New-style degrees set for reformed ARB accreditation
Following the ARB Tomorrow's Architects competency outcomes for Architects.
BSRIA Occupant Wellbeing survey BOW
Occupant satisfaction and wellbeing tool inc. physical environment, indoor facilities, functionality and accessibility.
Preserving, waterproofing and decorating buildings.
Many resources for visitors aswell as new features for members.
Using technology to empower communities
The Community data platform; capturing the DNA of a place and fostering participation, for better design.
Heat pump and wind turbine sound calculations for PDRs
MCS publish updated sound calculation standards for permitted development installations.
Homes England creates largest housing-led site in the North
Successful, 34 hectare land acquisition with the residential allocation now completed.
Scottish apprenticeship training proposals
General support although better accountability and transparency is sought.
The history of building regulations
A story of belated action in response to crisis.
Moisture, fire safety and emerging trends in living walls
How wet is your wall?
Current policy explained and newly published consultation by the UK and Welsh Governments.
British architecture 1919–39. Book review.
Conservation of listed prefabs in Moseley.
Energy industry calls for urgent reform.